May be applicable only to Brocade!!
System logs always show portIDs while referring to and SAN device error and it is aways tough to find the port details,
For eg:-
syslog: fctl: [ID 517869 kern. warning ] WARNING: fp(0)::PLOGI to 0x91300 failed. state=a reason=3. (Restricted Access Project)
In this error shows portID as 0x91300, so to determine which port is referring to, follow below process
NportID 0x91300
Start separating from left side… like 0x/9/13/00 <--
These values are in Hex format, to identify the actual port we have to Convert all Hex numbers to decimal.
9 when converted to decimal it is 9
When 13 is converted to decimal it is 19
So the device is connected to switch port 19 of domain id 9.
Another example:-
NportID 0xc91c00
Again start separating from left…
0x/c9/1c/00 <-
c9 is 201 in decimal and 1c is 28 in decimal. So device is connected to port 28 in domain ID 201.
But it seems this is only applicable to B series switches.